Laser [TDLS] O2 monitoring Transic100LP

Laser [TDLS] O2 monitoring Transic100LP

TRANSIC100LP – Transmitter for monitoring O2 in humid or aggressive process gases

TRANSIC100LP is ideally suitable for oxygen monitoring in moist and aggressive process gases. The compact gas spectrometer is based on a tunable diode laser. This measurement technology is well known for unmatched stability and durability. In many applications, the TRANSIC100LP can be flange mounted directly into a process. This results in real-time measuring values. For processes with high temperatures and pressures or at difficult mounting conditionsTRANSIC100LP can be configued with an optional sample cell close to the process in the slip stream.

Specifications

Measuring range
0 ... 5 Vol.-% / 0 ... 100 Vol.-%
Measuring principle
Diode laser spectroscopy (TDLS)
Ambient temperatures
–20 °C ... +60 °C
Interfaces
RS-232c / RS-485 / USB
Protection class
IP66
EX approval
II 1/2G Ex ib IIB T4 Gb,
II 2D Ex ib tb IIIC T85°C Db
Supply voltage
24V DC
Analogue outputs
1x 0/4 ... 20 mA, 500 Ω
Digital outputs
1 relay contact:
30 V AC, 1 A / 60 V DC, 0.5 A
Accuracy
≤ 0.2 Vol.-%
Response time
≤ 10 s
Measuring gas temperature
–20 °C ... +80 °C
Dimensions (H x W x D)
186 x 97 x 310mm
Weight
2.2 kg
Electrical safety
CE, FM

Video

Transic 100 TDLS O2 meting
Video afspelen

Features:

  • O2 transmitter based on high-performance laser spectroscopy (TDLS)
  • For use in use in explosion-hazardous areas (FM, ATEX and IECEx approvals)
  • Measurement directly in the process or extractive using a measurement gas cell (option)
  • Designed for heavy-duty industrial applications
  • Compact design and easy to operate
  • Long-term stability
  • No moving parts

Benefits:

  • Measures in real-time directly in the process
  • Easy installation and operation
  • Self-diagnostics with maintenance display
  • Low requirements for gas conditioning
  • Low operating costs: no consumables and no purging gas consumption
  • Rugged: reliable measurement even in contaminated gases

Applications:

  • Monitoring of inert gas blanketing in tanks and vessels
  • O2 measurement in process gases
  • Measurements in potentially explosive atmospheres
  • Process monitoring in fermenters and bioreactors
  • Room air monitoring
  • Quality monitoring for the production of technical gases
  • Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells