Modular System S700 – Gas analysis

Modular System S700 – Gas analysis

ModularSystem S700 – Gas analysis with system

The S700 modular system is very easy to configure to provide a tailor-made application. An S700 housing can be equipped with up to 3 analyzer modules for compact and cost-effective system solutions. A total of 6 different analyzer modules are available for analyzing more than 60 gas components.

Depending on the measuring task, installation site, and ambient conditions, the following housing types are available:

  • S710 19″ rack for analyzer cabinets and standard applications
  • S715 wall-mounting enclosure for harsh application conditions and zone 2 explosive environment (ATEX)
  • S720 flame-proof housing for zone 1 explosive environment (ATEX)

Specifications

Measuring principle
NDIR
Ambient temperatures
+5 °C ... +45 °C
Interfaces
RS-232c
Bus protocol
Modbus RTU
EX approval
Yes as option
Supply voltage
100 V / 115 V / 230 V - 48 ... 62 Hz
Analogue outputs
4x 4 ... 20mA, max. load 500Ω;
0 ... 10 V, electrically isolated
Analogue inputs
2x 0/2/4 ... 20mA
Option: 0 ... 10V DC
Digital outputs
8 Relay contacts:
30 V AC, 500mA / 48V DC, 500mA
3 relay outputs preset for failure, service and maintenance
8 Transistor outputs:
24V DC, 500mA Freely adjustable
Digital inputs
8 Optical coupler inputs:
24V DC electrically isolated, freely programmable
Detection limit
< 0,5% from the range
EN14181 QAL1 certificate
Yes
EN 15267-3 certificate
Yes
Heat up time
45 minuten
Measuring gas temperature
0 °C ... +45 °C
Temperatuur bij input analysator
Menu languages
Duits, Engels, Frans, Italiaans, Nederlands, Pools, Zweeds, Spaans
Display
LC-display
Electrical safety
CE, cCSUit
Max flow
Zonder geïntegreerde meetgaspomp: 5 l/h ... 100 l/h
Met geïntegreerde meetgaspomp: 30 l/h ... 60 l/h

Features:

  • 5 different measurement principles available
  • More than 60 measuring components to choose from
  • 3 different housing variants for different fields of application
  • Up to 3 analyzer modules in a single housing

Benefits:

  • Easy application-specific adaptation due to modular design
  • Also suitable for zone 1 and zone 2 explosive environments (ATEX)
  • Automatic adjustment with test gas or calibration cell
  • Integrated self-monitoring and fault diagnosis

Applications:

  • Emission measurement according to 13th (2001/80/EC), 17th (2000/76/EC), and 27th German Federal Emission Protection Directive (BImSchV).
  • Cooling gas monitoring of turbo generators
  • Measurement of CO for coal mill monitoring
  • Purity measurement of H2 in pressure swing adsorption plants
  • Monitoring of CO2 in natural gas in natural gas conditioning plants