Multi Component Analysis System MCS100E HW

Multi Component Analysis System MCS100E HW

The MCS100E HW is an analyzing system for extractive measurement of up to 8 IR-active gas compounds. It can be supplemented with oxygen and FID analyzer. From sampling probe to cell, all components that are in contact with the sample gas are heated to above the dew point and thus protected from corrosion. This hot measurement technique allows the measurement of the water soluble components HCl, NH3 and SO3.

Sulphur trioxide (SO3) is formed during the combustion of fossil fuels for power generation and is also used or produced in many industrial processes. At temperatures below about 200°C it combines with water vapor to form sulphuric acid which has deleterious effects on plant surfaces and on the environment.

Specifications

Measuring principle
NDIR
Ambient temperatures
+5 °C ... +35 °C
Met koelapparaat: +5 °C ... +50 °C
Interfaces
RS-232 / RS-485 / Ethernet
Bus protocol
Modbus RTU / PROFIBUS DP (option) / Modbus TCP (option)
Protection class
IP43
Conform
2001/80/EG, 2000/76/EG,
27.BImSchV, TA-lucht, EN 15267,
EN 14181:2004
Analogue outputs
4x 0/4 ... 20mA, max. belasting 500Ω
Max. 64 outputs with opto box via optical fibre possible
Analogue inputs
4x 0/4 ... 20mA
Max. 64 inputs with opto box via optical fibre possible
Digital outputs
12x 40V, 1A
Max. 64 outputs with opto box via optical fibre possible
Digital inputs
4x 50V AC, 4A / 24V DC, 4A
Max. 64 inputs with opto box via optical fibre possible
EN14181 QAL1 certificate
Yes
EN 15267-3 certificate
Yes
Response time
≤ 200 s; Depending on application
Measuring gas temperature
0 °C ... +1.300 °C
Dimensions (H x W x D)
2165 x 806 x 605mm
Electrical safety
CE
Max flow
200 l/h ... 1.000 l/h
Depending on application

Features:

  • Extractive measurement of up to 8 IR-active gas components
  • Additional oxygen and total hydrocarbon analyzer as option
  • Gas lines heated throughout
  • Sample gas infeed on gas sampling probe or analyzer
  • Back-purging of gas sampling probe for filter cleaning
  • Rapid measured gas exchange to minimize adsorption and desorption processes
  • Automated sample point switching

Benefits:

  • Measurement of several gas components with one analyzer
  • Heated gas paths enables measurement of difficult gases like HCl and NH3
  • Long maintenance intervals (typically 6 months) due to self monitoring of the analyzer
  • Selective measurement of NO and NO2 – no converter required
  • QAL3 drift test with internal calibration filter wheel – no test gas required

Applications:

  • Emission monitoring of waste incineration plants
  • Monitoring of combustion plants with secondary fuels
  • Flue gas monitoring in cement plants
  • Emission monitoring of refineries
  • Emission monitoring of heavy oil fired diesel engines