PFM 2 Ex Dust sensor Dr. Födsch

PFM 2 Ex Continuous,  dust sensor, triboelectric monitoring of dust emissions

The PFM 2Ex is a very sensitive analyzer for continuous measurement of dust emissions. The dust measurement meets the highest international and European standards.
This simple measurement is very suitable for emission measurement at waste incineration plants  and other combustion plants.

The PFM 02 Ex serves the permanent control of dustemissions. It can be applied as a filter monitoring deviceas well as configured as a dust measuring device in potentially explosive atmospheres.

The robust design ensures a long lifespan > 10 – 15 years.

Specifications

Measuring principal
tribo-elektric
Ambient temperature
-20 ‐ 50°C
Maximum flue gas temperature
280 °C
Interface
USB for connection with PC
Modbus 485
IP kraiting
IP65
Housing
Aluminium
Analog outputs
2x 4 - 20 mA
Analog inputs
1 x 4...20 mA for external speed v [m/s], galvanically isolated
power supply
110...240 V AC, 50...60 Hz, fuse 1 AT, 10 W; pre-fuse: min. 1.2 AT
24 V DC (optional), 10 W; pre-fuse: min. 500 mAT
Dimensions
130 mm x 170 mm x 530/730 mm
Weight
2.1kg at probe 300mm

Downloads

Features PFM 20-D tribo  dust sensor

 

  • automatic zero and reference point control
  • compact probe head and coated probe rod
  • adjustable lengths and force of the probe rod
  • Modbus RS 485, analog and digital signal output (optional)
  • connectivity for external display and control unit (DUx 20; optional)
  • robust analyzer, long-term stability

Your benefits

 

  • compact device consisting of probe and operating unit → no separate operating device
    necessary
  • variable application possibilities through probe
    rod modification
  • local diagnosis of system state by integrated
    graphic display
  • real-time display with diagram or in text mode
    with display in % or mg/m³
  • no purge air blower required
  • low operational costs
  • easy mounting
  • Atex