Sick MCS200 Emission Monitoring System hot wet CEMS
Sick NDIR Multi Component Analyser System CEMS MCS200
CEMS based on NDIR technology. An analysis system that performs all tasks for accurate emission monitoring: more than 10 components are measured simultaneously.
A main objective of this Sick CEMS MCS200 development is to realize an analyzer with low maintenance requirement and high analysis accuracy for components such as HCl, SO2, NO, NO2, CO, CO2, CH4, N2O, NH3 and H2O.
The Sick MCS200 CEMS TÜV has recently been approved, including a total hydrocarbon FID analyser, the Sick GMS800 Fidor. This is an FID analyser whose detector directly branches off the sample from the sampling line. The advantage is that you do not need a separate sample line and sampling probe. Perhaps unnecessarily: the FID has also been tested on the basis of NEN-EN 15267-3 by the TÜV and is part of the TÜV certificate.
Unique is that the MCS200 can be equipped with the option of fully automatic calibration. To achieve this, a so-called “optical filter wheel” can be built in, which allows calibrations without the use of standard gases. Of course entirely in accordance with the QAL3 EN14181: 2014 standard.
This gives you two main advantages: an economic advantage and a higher availability. The economic advantage lies mainly in the fact that no costs are made for standard gases, cylinder rental, depreciation, reduction, etc. In addition, the calibration with the “optical filter wheel” is fully automatic and therefore no man-days are required. The start of this calibration cycle can even be initiated by the emission registration system.
Specifications
27.BImSchV, TA-lucht, EN 15267,
EN 14181, MCERTS
Number depending on system configuration, galvanically isolated, max. 32 outputs
Number depending on system configuration, galvanically isolated, max. 32 inputs
Number depending on system configuration, galvanically isolated, max. 64 outputs
Number depending on system configuration, max. 64 inputs
Status-LED's: *Power*, *Maintenance* and *Failure*
Downloads
Brochures
Manuals
Certificates
Hot Topics Sick MCS200:
- Operation via touchscreen
- Automatic adjustment of the analyzer
- Automatic backwashing and filter cleaning of the sampling unit
- Measurement of up to 10 IR components plus O2 and total hydrocarbons (CxHy)
- Extractive analysis method
- Maintenance-free gas transport using an ejector pump
- Calibration with internal filter wheel calibration
- Certified digital Modbus® interface
- Web server for device control independent of the operating system used
- Use of dry test gases with HCl and NH3
Benefits Sick MCS200:
- Real limit value monitoring
CO, NO, NO2, N2O, SO2, HCL, NH3, CH3, CO2, H2O, O2 and CxHy certified in accordance with EN 15267-1: 2009, EN15267-2: 2009, EN15267-3: 2007 and EN14181: 2014 - Only one analyzer for 12 measuring components
- Easy to integrate into the customer’s network environment
- Long maintenance interval of 6 months for many measuring components
- Suitability-tested measurement of greenhouse gases such as N2O, CH4 and CO2
- Low maintenance costs
Applications Sick MCS200:
- Emission monitoring at waste incineration plants
- Power plants
- Co-firing installations, eg cement factories
- Measurement of nitrogen oxides (NO, NO2, N2O)
- SO3 monitoring in, for example, coal-fired power stations