Qal1 flowmeter FMD09

Qal1 Flowmeter FMD09

A proven measurement technique to determine a flow rate is the differential pressure FMD 09 Flowmeter (dP measurement). An obstruction is placed in a pipe. The measured pressure difference across this obstruction is proportional to the flow rate.

The most well-known is the measuring plate orifice , including measuring flange. The measuring plate consists of a flat metal plate with a round hole in the middle, which is usually clamped between 2 flanges. 2 pressure measurement points (tapping is in English) are placed in front of and behind the measuring plate. The measured pressure difference is quadratic with the flow.

By measuring additional parameters via the evaluation unit, the process flow rate can be converted to a flow rate at standard conditions. Other measuring components can be corrected to standard conditions using this flow rate.

With emission measurements (CEMS) the current concentrations are determined. For conversion to mass one needs the volume, which is calculated from the gas velocity. This ultimately allows the freight to be determined via software .

 

Dr Fodisch Qal1 Flowmeter FMD09

Specificaties

Measuring range
(0)3–40 m/s
Measuring principal
Pressure difference
Ambient Temperature
-20 ... +50°C
IP rating
IP65
Channel diameter
0.4 ... 8m
Power supply
24 DC 115 / 230V AC, 50 / 60 Hz
Power consumption
5 Watt
Analog outputs
0/4 ... 20mA, max. load 500Ω
Digital outputs
2 relais otputs, max 48 V/ 0.5 A
accuracy
<2% from measuring range
Detection limit
<3m/s
QAL1 certificaat
yes
EN 15267-3 certificaat
yes
Flue gas temperature
Above Dewpoint, -20…280 °C standard, other temperatures on request
Dimensions (H x B x w)
1200 mm x 640 mm x 440 mm
Weight
9.5 kg
Insertion lenght
500 mm (standard)

Features Dr Fodisch Qal1 Flowmeter FMD09:

  • Reliable measurement of gas velocity, even at high temperatures
  • Reliable measurement of the gas temperature
  • Reliable measurement of the gas absolute pressure
  • Calculation of volume flow at standard conditions
  • Automatic zero check option
  • QAL 1 Certified, cost-effective measurement system
  • Versions with or without counter-support and for point measurement
  • Very low maintenance, maintenance interval 6 months
  • Convenient operation via remote access with web interface

Applications Dr Fodisch Qal1 Flowmeter FMD09 :

  • Volume flow measurement at high temperatures
  • Volume flow measurement at high pressure
  • Plants with large or small flue gas duct cross-sections
  • Waste energy plants
  • Refineries
  • Power plants