D-R 320 Scattered light dust monitor

D-R 320 Scattered light dust monitor

The new dust monitor D-R 320 is based on the back scattering principle. The light of a laser diode illuminates the dust particles in the measuring volume of the flue gas duct. The light scattered backwards by these particles is detected and evaluated. The D-R 320 does not require a light trap. The background light in the stack is detected by means of a special system with integrated dual detector and automatically compensated.

 

Specifications

Measuring range
0 ... 5 / 0 ... 200 mg/m³
Measuring principle
Back scattering principe
Ambient temperatures
40 ... +60 °C
Interfaces
Modbus
Bus protocol
RTU
Protection class
IP65
EX approval
Optional zone II 3G EX PZ II T4
Channel diameter
max 20m
Supply voltage
24V DC
Analogue outputs
1x 4 ... 20mA, 400Ω
Digital outputs
2 relay outputs, permissible load 60V DC / 30V AC / 0.5 A
EN14181 QAL1 certificate
Yes
EN 15267-3 certificate
Yes
Response time
> 1 sec … 180 sec, parameterisable
Measuring gas temperature
0 … +600°C (+32 …+1112°F)
Dimensions (H x W x D)
200 x 190 x 260/410mm, length depending on the variant
Purge air connection
Ø 40mm, IP6
Weight
12 kg

Video

Durag D-R 320 stofmeter
Video afspelen

Features: D-R 320 dust monitor

  • Continuous measurement of dust concentration
  • Easy installation on standard flanges
  • Easy startup without adjustment
  • Automatic background light compensation, no light trap
  • Convenient operation, remote access possible
  • Automatic control functions
  • Integrated purge air monitoring and control
  • Long service intervals
  • Certified acc. to EN 15267
  • Integrated fail safe shutter as an option
  • Data transfer via Modbus compliant with VDI 4201-3

Applications: D-R 320 dust monitor

Continuous emission monitoring, e.g.:

  • On incineration plants generally
  • On plants according to IED 2010/75/EU
  • On plants according to 2001/80/EC LCPD
  • On waste, hazardous waste and sewage sludge incineration plants
  • On cement manufacturing plants
  • On power plants with gas, oil, coal or cofiring
  • On plants for the incineration of biomass

Monitoring of: D-R 320 dust monitor

  • Ventilation units
  • Filter units